Dades diàries del sensor de soroll ubicat al barri de Russafa, en el carrer Capellà Femenía, 14
Data and Resources
Additional Info
Field | Value |
---|---|
Title (in Spanish) | Datos diarios del sensor de ruído ubicado en el barrio de Ruzafa, en la calle Cura Femenía, 14 |
Title (in English) | Daily data from the noise sensor located in the Ruzafa neighborhood, in Cura Femenía Street, 14 |
Decription (in Spanish) | Datos diarios del sensor de ruido ubicado en el barrio de Ruzafa y en concreto en la calle Cura Femenía, 14 (T251234). Su ubicación exacta es: 39.46227, -0.3732538. A continuación se explica cada una de las columnas del recurso. * RecvTime: Dato proporcionado por la plataforma de ciudad VLCi. Fecha en la que se insertó el dato en la plataforma. * FiwareServicePath: Dato proporcionado por la plataforma de ciudad VLCi. Servicio de la plataforma VLCi al que pertenece el sensor. * EntityType: Dato proporcionado por la plataforma de ciudad VLCi. Tipo de entidad del sensor en la plataforma VLCi. * EntityId: Dato proporcionado por la plataforma de ciudad VLCi. Identificador único del sensor en la plataforma VLCi. * LAeq: Nivel sonoro continuo equivalente. Se define en la ISO 1996-2:2017 como el valor del nivel de presión en dBA en ponderación A de un sonido estable que en un intervalo de tiempo T posee la misma presión sonora cuadrática media que el sonido que se mide y cuyo nivel varía con el tiempo. En este caso el período establecida para este sensor es de 1 minuto. * LAeq_d: Es un indicador de ruido asociado al día, donde al día le corresponden 12 horas, en el período que se extiende desde las 7 hasta las 19 horas. * LAeq_den: índice de ruido día-tarde-noche, es utilizado para determinar la molestia vinculada a la exposición al ruido. * LAeq_e: Es un indicador del nivel sonoro durante la tarde, donde a la tarde le corresponden 4 horas, en el período que se extiende desde las 19 hasta las 23 horas. * LAeq_n: Es un indicador del nivel sonoro durante la noche, donde a la noche le corresponden 8 horas, en el período que se extiende desde las 23 hasta las 7 horas. * Dateobserved: Día al que se refieren las medidas. |
Decription (in English) | Daily data from the noise sensor located in the Ruzafa neighborhood, in Cura Femenía Street, 14 (T251234). Its exact location is: 39.46227, -0.3732538. Now, it's explained each column of the resource: * RecvTime: Data provided by the VLCi city platform. Date on which the data was inserted in the platform. * FiwareServicePath: Data provided by the VLCi city platform. VLCi platform service to which the sensor belongs. * EntityType: Data provided by the VLCi city platform. Sensor entity type on the VLCi platform. * EntityId: Data provided by the VLCi city platform. Unique identifier of the sensor on the VLCi platform. * LAeq: Equivalent continuous sound level. It is defined in ISO 1996-2: 2017 as the value of the pressure level in dBA in A-weighting of a stable sound that in a time interval T has the same root mean square sound pressure as the sound that is measured and whose level varies over time. In this case, the period set for this sensor is 1 minute. * LAeq_d: It is a noise indicator associated with the day, where 12 hours correspond to the day, in the period from 7 am to 7 pm. * LAeq_den: day-afternoon-night noise index, it is used to determine the annoyance linked to noise exposure. * LAeq_e: It is an indicator of the sound level during the afternoon, where 4 hours correspond to the afternoon, in the period that extends from 7:00 p.m. to 11:00 p.m. * LAeq_n: It is an indicator of the sound level during the night, where 8 hours correspond to the night, in the period that extends from 23 to 7 hours. * Dateobserved: Day to which the measurements refer. |
Name (in Spanish) | |
Name (in english) | |
Name (in valencian) | |
Keywords (in Spanish) | |
Keywords (in English) | |
Data source | |
Openness score | 4 stars (Data linkable via URIs (eg. RDF)) |
Last updated known | |
Update frequency | P0Y0M1DT0H0M0S |
Language(s) | |
Geographic coverage | |
Time coverage (from) | |
Time coverage (to) | |
Validity | |
Related resource(s) | |
Normative(s) |